Our medical gas outlets have very good quality.
Medical gas outlets are critical components of a medical gas system, designed to deliver essential gases for daily medical care. These outlets are installed at key delivery points such as wardroom bed head units, medical pendants, and equipment walls, providing the necessary medical gases required for patient care.
At LAX AIR MED CONSTRUCTION, our medical gas outlets are engineered for durability, safety, and ease of use, ensuring compliance with the highest international standards. These outlets are found in critical care areas like operating theatres, intensive care units (ICUs), emergency rooms, recovery rooms, and patient wards. They provide the necessary gases for life-saving procedures and patient care, ensuring a reliable supply that meets clinical demands.
Medical gas outlets are critical components in modern healthcare settings, providing direct access to essential medical gases such as oxygen, nitrous oxide, medical air, carbon dioxide, and vacuum (suction). These outlets ensure that healthcare professionals can safely and efficiently connect life-support equipment, ventilators, anesthesia systems, and other medical devices that require a continuous supply of medical gases.
Medical gas outlets in ORs provide critical access to gases like oxygen, nitrous oxide, and medical air. These gases are used in anesthesia machines, ventilation systems, and surgical equipment, ensuring that patients receive the necessary care during surgery.
In ICUs, medical gas outlets supply oxygen and medical air for life-support systems and ventilators. They are vital for maintaining patient care and monitoring during critical health conditions, ensuring continuous support for respiratory needs.
In general hospital wards and patient rooms, medical gas outlets are used to deliver oxygen, medical air, and vacuum systems for everyday patient care. They are crucial for providing oxygen therapy, suction for airway management, and other supportive care.
Emergency rooms rely on medical gas outlets to provide immediate access to oxygen and other gases in life-threatening situations. These outlets ensure that medical staff can quickly connect life-saving equipment like resuscitation devices and oxygen therapy units during emergencies.
In neonatal and pediatric intensive care units, specialized medical gas outlets are used to provide gentle and precisely controlled oxygen for infants and young patients with delicate respiratory systems.
After surgery, patients are taken to recovery rooms where medical gas outlets supply oxygen and medical air for postoperative care. These gases are critical for stabilizing patients and supporting recovery after anesthesia.
Medical gas outlets are also used in dental and veterinary clinics for anesthesia delivery, oxygen support, and vacuum systems to maintain a sterile and safe environment during procedures.
Generic Name | Applicable Standards | Lax Air Brand Name | Variants |
---|---|---|---|
Terminal Unit/ Outlet with Connector/Probe | IS/ISO 9170-1:2017 IS/ISO 73961: 2016 A1:2017 IS/ISO 7396-1:2016+ A1:2017 HTM 02-01 |
BRITISH STANDARD BRITISH STANDARD (metal) |
O2 VACUUM, AIR 4, N2O, AIR 7, CO2 |
IS/ISO 9170-1:2017 CGA V-5-2019 IS/ISO 9170-1:2017 IS/ISO 7396-1:2016+ A1:2017 DIN 13620-2 |
DISS DIN |
O2 VACUUM, AIR 4, N2O, AIR 7, CO2 ENTONOX, TRI-GAS O2 VACUUM, AIR 4, N2O, AIR 7 |
|
IS / ISO 9170 - 1: 2017 | PURITAN BENNETT (PB) Compatible O, VACUUM, AIR 4, NO. OHMEDA (Diamond) O, VACUUM, AIR 4, N Q Compatible |
CO2 VACUUM, AIR 4, N2O CO2 VACUUM, AIR 4, NQ |
|
IS/ISO 9170-2:2008 IS/ISO 7396 2: 2007 IS/ISO 9170-2:2008 CGA V-5-2019 |
BS - AGSS DISS - AGSS |
02, VACUUM, AIR 4, N Q | |
Flow - metering Device | IS / ISO 15002: 2008 IS / ISO 7396 - 1: 2016 + A1:2017 |
0 - 70 lpm 0 - 40 lpm 0 - 15 lpm 0 - 5 lpm 0 - 3 lpm |
|
Humidifier Bottle | IS / ISO 201789: 2018 | 200 ml | |
Medical Suction Devices | IS / ISO 10079-3:2014 IS / ISO 7396 - 1: 2016 + A1: 2017 HTM 02-01 PART A- 2006 Class llb - MDR 2017/745 |
Controllable Vacuum: 0 to 300 mmHg Controllable Vacuum: 0 to 100 mmHg 600, 1000, 1750, 3500 ml 800, 1000, 1750, 3500 ml (DISS) |
|
IS / ISO 10079 - 3: 2014 IS / ISO 7396 - 1: 2016 + A1: 2017 IS / ISO 9170 - 1: 2017 HTM 02-01 PART A- 2006 |
Mobile Suction Trolley |
Metal outlet has been developed to address
the long-standing need to simplify the
service requirement without supply disruption
once installed the servicing/maintenance is
possible without removing the enclosure
making downtime to bare minimum for all
types of mounting. Wall pendant column bed
head outlets. Increase in life cycle of the
device is an Additional benefit.
Gas Services | Pressure | Flow Lpm |
O2,NO,CO,Medical Air(ar 4) & Mixedn Gases | 58 psi (4 bar) | 130 |
Air for Surgical Tools (AR 7) / Air Motor | 102 psi (7 bar) | 350 |
Medical Vacuum (below atmosphere) | 450mmHg (8.7psi) | 85 |
German DIN Standard Medical Gas Outlets are installed at
medical gas systems delivery points. The base part made
of brass alloy. Twice outlet connection With shut-of valve
can maintain without having to interrupt gas delivery to
other outlets. Only accept German DIN standard quick
connect adapters. Different gas types with different
quick – connect adapters.